Fitting Guide

  • Valley Contax offers the best choice among progressive Multifocal lenses for today's presbyopic population.

  • The Platinum Eye™ Multifocal is a simultaneous aspheric design.

  • Recommended in Boston XO.

The Platinum Eye™ provides ultimate comfort, stability and acuity at near, intermediate and distance. It offers add power up to 3.00 D and accurate correction up to 1.75 D of corneal astigmatism and attainable distance VA of 20/20.

The fitting for the Platinum Eye™ Multifocal is simple and sure.

The aspheric measurements are designed to provide optimal corneal alignment when fit to given specifications. Platinum Eye™ functions as a stepping-stone for creating add power from center to edge. Platinum Eye™utilized the front enhancements feature without altering the original Golden Eye™ fit. Platinum Eye™ and Golden Eye™ are recommended in Boston XO™ and available in all color choices.

Platinum Eye™ and Golden Eye™ are the preferred Multifocal exclusively from Valley Contax.

That means Valley Contax has complete and ultimate parameter control for quality and reproducibility. Purchase Platinum Eye™ and Golden Eye™ Multifocals with the Valley Contax Failsafe Warranty (credit is issued for up to three lenses per eye. Each credit is charged a button recovery fee or you may choose to order unwarranted.

The Platinum Eye™ and Golden Eye ™ are available exclusively from Valley Contax in a wide range of parameters:

Base Curves: Any base curve radius

Powers: Made to order

Diameters: Suggested sizes - 9.2 through 9.8

Edge Lift:

Platinum Eye™ A 10% less edge lift than standard
Platinum Eye™ B Standard edge lift
Platinum Eye™ B 10% - 15% more edge lift that standard

Parameter Selection

Corneal Cylinder Base Curve
(Steeper than flat K)
Power
(Add to distance spectacle)
0.00 to 2.00D 1.75D steeper add -1.75
2.25D 2.00D steeper add -2.00
2.50D 2.25D steeper add -2.25
  (Platinum Eye™ C)  


Base Curve Diameter
7.10 and steeper 9.2
7.20 to 7.50 9.4
7.60 to 8.00 9.6
8.10 and flatter 9.8

Lens Fitting

  Centration is important. The over-refraction is valid only when the lens centers well.
1. Lens should be well centered with mid-peripheral alignment and slight central pooling.
2. With lens centered, check distance acuity monocularity. Over-refract if necessary in 0.25D steps using hand held lenses to 20/20.
3. Check distance acuity binocularly. Over-refract if necessary in 0.25D steps using hand held lenses to 20/20.
4. Check near acuity with distance over-refraction still in place. If near vision has been compromised, add +0.25D to the non-dominant eye.



Problem solving techniques
 
1. A decentered lens may require a steeper base curve of at least 0.1 mm.
2. A superior positioning lens with too much edge lift may require a reduction of edge lift by 10% or (Golden Eye™ A).
3. A superior positioning lens with normal edge lift may require increased center thickness or steeper base curve.
4. A lens that is not positioning laterally may require a larger diameter.

When a lens is not centered, measure the position.